75 kVA / 82.5 kVA / 100 kVA / 125 kVA - Power Genset

Mahindra Powerol Diesel Generator

FEATURES:

  • COMPACT DESIGN

    • Its recovery time, easily the best in its category, guarantees a seamless switchover to the back-up power. Moreover, its effective governing system controls the voltage fluctuations, thus ensuing complete safety of your equipments.
  • LARGE FUEL TANK

    • Its got one of the most preferred engines fitted inside - the Mahindra Powerol engine. Compact and low on vibration, this engine has the smallest footprint as compared to other engines of identical ratings. Making the DG set apt even for roof-mountings.
  • LONGER ENGINE LIFE

    • Each and every Powerol DG set complies with the most stringent noise and emission norms stipulated by the Central Pollution Control Board of India (CPCB).
  • LOW MAINTENANCE COST

    • It’s got other advantages too. Like, it’s transported through the Mahindra Transport Solutions Group. It is installed and commissioned through a Mahindra authorized dealer. It even comes with an annual maintenance contract. It is most fuel efficient in its class It offers zero-leak engines Manual and AMF control panel options are also available
  • PREFERRED BY ALL

    • A Powerol DG set can be used in the Telecom, Defence and Railway sectors. It can also be installed at places like petrol pumps, hospitals, super markets, banks and construction sites

Discription   DESCRIPTION

 

Silence is Golden: India’s most silent Genset brand

Mahindra Powerol’s ‘Spectro’ series of diesel gensets is one of the most silent gensets manufactured by the brand. It has sturdy wheels and a long handle which allows easy mobility of the genset.

Discription  ASSURANCE

 

Power fluctuations can affect your business as well as day to day operations. Diesel gensets act as back up against power cuts providing you with uninterrupted power supply. Mahindra Powerol has a wide network of authorized dealers & skilled service engineers spread across India. Customers just need to dial our Toll-free number – 1-800-419-1999 & service will be available at the doorstep.

  • Over 400 sales and service touch points.
  • Easy Finance schemes available.
  • Fuel Efficient Engines.

APPLIANCES THAT CAN RUN ON GENSET

1 REFIGERATOR
1 MICROWAVE
6 LIGHTS
1 COFFEE MAKER
2 AC’S
3 LAPTOPS
1 MONITOR
1 PRINTER
1 SATELLITE DECODER (150~200 watts)
1 WI-FI MODEM (150 watts)
1 LAPTOP (180 watts)
1 CELL CHARGER (< 100 watts)
2 TV (200~300 watts)
2 SATELLITE DECODER (150~200 watts)
2 WI-FI MODEM (150 watts)
2 LAPTOP (180 watts)
2 CELL CHARGER (< 100 watts)

SEGMENTS USED FOR

BUNGALOWS - SMALL OFFICES - SMALL SHOPS

TECHNICAL SPECIFICATIONS

Print
PARAMETERS DG MODELS
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 75 kVA
Rated(kWe) 60
Engine Model 41035 GM-C2
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 104.4
Governing class G2
Starting system 12 V DC Elec
Fuel tank capacity 180
Genset Dimension (LxWxH $$) (mm) Approx. 3000 X 1150 X 2135
Genset Weight (kg) approx. 1350
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra
Power Output# (HP) 103
Aspiration Turbocharged Intercooled
Bore x Stroke (mm) 96 x 122
Displacement (Lit) 3532
Fuel consumption @ 75% load (lit/hr) ^ 13.5
Fuel consumption @ 100% load (lit/hr) ^ 17.8
Lube oil specification SAE15W40 CI4
Total lubrication system capacity (lit) 10
Lube Oil Consumtion (lit/hr) $ 0.1% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
600 hrs. for Oil change
Radiator coolant capacity (liter) 19
Alternator
Make CG/LS
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

 

PARAMETERS DG MODELS
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 82.5 kVA
Rated(kWe) 66
Engine Model 41125A GM-C2
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 114.8
Governing class G2
Starting system 12 V DC Elec
Fuel tank capacity 160
Genset Dimension (LxWxH $$) (mm) Approx. 2950 X 1075 X 1575
Genset Weight (kg) approx. 1500
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra
Power Output# (HP) 111.5
Aspiration Turbocharged Intercooled
Bore x Stroke (mm) 96 x 132
Displacement (Lit) 3882
Fuel consumption @ 75% load (lit/hr) ^ 13.5
Fuel consumption @ 100% load (lit/hr) ^ 18.1
Lube oil specification SAE15W40 CI4
Total lubrication system capacity (lit) 13.5
Lube Oil Consumtion (lit/hr) $ 0.1% of Fuel Consumption
Lube oil change period (hrs.) 300 hrs. for Oil Top Up
600 hrs. for Oil change
Radiator coolant capacity (liter) 19
Alternator
Make CG/LS
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

 

PARAMETERS DG MODELS
Duty (Standby/ Prime) Prime
50 HZ PRIME Rating(kVA) 100 kVA
Rated(kWe) 80
Engine Model mPower41265G
No of Cylinders 4
Phase / Voltage (V) 3 / 415
Power Factor 0.8 (lagging)
Current (A) 139
Governing class G2
Starting system 12 V DC Elec
Fuel tank capacity 250
Genset Dimension (LxWxH $$) (mm) Approx. 3500 x 1230 x 1425
Genset Weight (kg) approx. 1650
Rated Speed RPM 50/1500
Engine Specification
Make / Series Mahindra mpower
Power Output# (HP) 126
Aspiration Turbocharged Aftercooled
Bore x Stroke (mm) 105 x 137
Displacement (Lit) 4800
Fuel consumption @ 75% load (lit/hr) ^ 17.3
Fuel consumption @ 100% load (lit/hr) ^ 23.1
Lube oil specification SAE 15W40CI4+
Total lubrication system capacity (lit) 13.5
Lube Oil Consumtion (lit/hr) $ < 0.1% of Fuel Consumption
Lube oil change period (hrs.) 500
Radiator coolant capacity (liter) 19
Alternator
Make CG/LS/Stamford/Equivalent
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

 

PARAMETERS DG MODELS
Duty (Standby/ Prime) Standby Prime
50 HZ PRIME Rating(kVA) 125 kVA
Rated(kWe) 100
Engine Model mPower41565G mPower61565G
No of Cylinders 4 6
Phase / Voltage (V) 3 / 415 3 / 415
Power Factor 0.8 (lagging) 0.8 (lagging)
Current (A) 173.7 173.7
Governing class G2 G2
Starting system 12 V DC Elec 24 V DC Elec
Fuel tank capacity 250 250
Genset Dimension (LxWxH $$) (mm) Approx. 3500 x 1230 x 1425
Genset Weight (kg) approx. 1650 1855
Rated Speed RPM 50/1500 50/1500
Engine Specification
Make / Series Mahindra mpower
Power Output# (HP) 156
Aspiration Turbocharged Aftercooled
Bore x Stroke (mm) 105 x 137
Displacement (Lit) 4800 7200
Fuel consumption @ 75% load (lit/hr) ^ 21.4 21.4
Fuel consumption @ 100% load (lit/hr) ^ 28 28
Lube oil specification SAE 15W40CI4+
Total lubrication system capacity (lit) 13.5 20.2
Lube Oil Consumtion (lit/hr) $ < 0.1% of Fuel Consumption < 0.1% of Fuel Consumption
Lube oil change period (hrs.) 500 500
Radiator coolant capacity (liter) 19 22.5
Alternator
Make CG/LS/Stamford/Equivalent
Enclosure Type IP23
Voltage regulation ±1%
Class of insulation Class H
Maximum Unbalanced Load across Phases 25%

All Specifications are at Standard NTP operating conditions
^ Considering 0.845 Specific Gravity of diesel, +5 % Tolerance
# Engine Power at 110 % load
Fuel -High Speed diesel (HSD IS 1460:2005)
* Represent the Standby Ratings
$ Considering 0.89 Specific Gravity of Oil
Engine Power will have ± 5 % Tolerance
** For CG only 3 Phase Configuration available
$$Height Without Silencer

 

PRODUCT RANGES